medOS ultra
ProductsmedOS ClinicalCompounding Room

medOS Clinical

Compounding Room

USP <797>/<800> sterile admixture, every pillar optional

A capability matrix turns a generic dispense worklist into a global-standard IV admixture workspace: recipe calculation, barcode verification, gravimetric checks, photo capture, hazardous-drug checklists and forced double-checks — each independently switchable per hospital.

compounding-room — USP <797>/<800> admixture
WORKSHEETCR-66-0211
IngredientDoseVolume
Vancomycin HCl1 g20 mL
NaCl 0.9%230 mL
Final admixture1 g250 mL

calc concentration = 4.0 mg/mL

BUD 24h @ 2–8°C · infuse ≥ 60 min

supervisedthroughputsimulation
PILLARS

BCMA barcode

3/3 scans matched

ON

Gravimetric verify

tolerance ±5% · 4.2 g / 4.0 g

ON

Photo capture

step 2 of 4 captured

ON

USP 800 hazardous

non-hazardous recipe

OFF

Double-check

awaiting 2nd pharmacist

ON

Capabilities

Ingredient recipe + dose/volume/concentration calculation

BCMA barcode + gravimetric/volumetric verification with tolerance dial

USP 800 hazardous checklist + forced independent double-check

Per-step photo capture and beyond-use dating

Three work modes: supervised (teaching co-sign), throughput, simulation

See Compounding Room on your workflows

Ask Anything